Comparison of the human brain is mixed with respect to the control system of the cement mixingstation, by him to control all the limbs and action. If there is a problem of the whole system,concrete mixing station are unable to work, we Zhengzhou Lijie is specialized in the production ofconcrete mixing station manufacturers, to explain to you if you have a problem to control systemhow to repair.
Fault phenomenon: an aggregate balance, using the cantilever beam sensor, rated load is 5 tons,1 tons of good linearity, but more than 1 tons, the linear is poor, and the bigger the linearity is not good, the electrical resistance method, voltage and pressure angle method examination is verygood. The careful observation, found that the strain which has a sensor has accumulated material,clear, all normal. The reason for this failure is the large range sensors, deformation does not occur in a small weight, but the increase of weight sensor, micro deformation will occur, if the object effect of deformation, the sensor output is not linear. We must pay attention to the installation beam sensors, one end fixed sensor can not exceed the strain, strain area beam type sensor is generally in the middle, appearance than the ends to be narrow, installation must not affect the strain area
Haomei machinery equipment CO., LTD.
Email: ann@haomei.biz
Website: http://www.truck-mixer-cn.com
Office Add: No.14 Waihuan Road, New district, Zhengzhou, China
Tel: +86-371-65621392
Fax:+86-371-86616825